Nexlar E-Commerce

West Penn Wire 25225BWH1000 16/1PR STRD UNSHLD Plenum 1000ft – White

SKU : 25225BWH1000 Category

The 25225BWH1000 cable features 16 individual conductors, each with a stranded, unshielded design. The conductors are made of high-quality copper, ensuring excellent conductivity and signal transmission capabilities. The cable follows a twisted pair configuration, where two conductors within each pair are twisted together. This configuration helps minimize electromagnetic interference and crosstalk, ensuring clean and clear signal transmission.

West Penn Wire 25225BWH1000 16/1PR STRD UNSHLD Plenum

1000ft – White

The individual conductors are insulated with a specialized

material, providing electrical insulation and protection against

signal interference. Each twisted pair is color-coded or numbered

for easy identification during installation, ensuring correct pairing

and maintaining signal integrity. The cable’s outer jacket is made

of a plenum-rated material, which is typically low-smoke, flame-

retardant, and designed for use in plenum spaces to meet fire

safety regulations.
The white color of the cable’s jacket provides a clean and

professional appearance. It comes in a generous length of 1000

feet, offering ample cable for extended runs and installations. The

cable may feature sequential footage markings along its length,

assisting with measurement and tracking during installation. It is

suitable for in-wall, in-ceiling, or plenum installations, where

quality and safety are essential.
The West Penn Wire 25225BWH1000 cable meets industry standards

and certifications, ensuring its quality and safety. It complies with

plenum rating requirements, making it suitable for installation in

plenum spaces where air circulation and fire safety are critical.

The cable is designed for easy termination and offers reliable

performance, making it an ideal choice for audio and

communication applications.

Specifications

  • Conductor Gauge: The cable features specific conductorgauges, such as 16 AWG (American Wire Gauge), indicating the

    thickness of the individual conductors. Thicker conductors

    generally offer lower resistance and improved signal quality.

  • Conductor Material: The conductors in the cable are made ofhigh-quality copper, offering excellent conductivity and signal

    transmission capabilities.

  • Insulation Material: The individual conductors are insulated witha specialized material, providing electrical insulation and

    protection against signal interference.

  • Pair Identification: Each twisted pair in the cable is color-coded or numbered for easy identification during installation,

    ensuring correct pairing and maintaining signal integrity.

  • Twisted Pair Configuration: The cable utilizes a twisted pairconfiguration, where two conductors within each pair are twisted

    together, reducing electromagnetic interference and

    crosstalk.

  • Pair Separation: The twisted pairs in the cable are separatedfrom each other, minimizing interference between adjacent pairs

    and maintaining signal isolation.

  • Jacket Material: The cable’s outer jacket is made of a plenum-rated material, which is typically low-smoke, flame-retardant, and

    designed for use in plenum spaces to meet fire safety

    regulations.

  • Jacket Thickness: The cable’s outer jacket has a specificthickness, contributing to its overall durability and protection of

    the internal conductors.

  • Oxygen Transmission Rate (OTR): The cable’s jacket may have aspecified OTR, indicating its ability to prevent the transmission of

    oxygen. This is important in plenum spaces where the risk of fire

    needs to be minimized.

  • Smoke Density Rating: The cable may have a specific smokedensity rating, such as ANSI/UL 910 or ASTM E662, which measures

    the amount of smoke emitted in the event of a fire. A lower

    smoke density rating indicates reduced smoke production.

  • Toxic Gas Emission: The cable’s construction may limit theemission of toxic gases in case of fire, ensuring the safety of

    personnel in the surrounding area.

  • Jacket Color: The cable’s jacket is white in color, providing aclean and aesthetically pleasing appearance.
  • Cable Length: The cable comes in a length of 1000 feet,offering ample cable for extended runs and installations.
  • Cable Markings: The cable may feature sequential footagemarkings along its length, assisting with measurement and tracking

    during installation.

  • Voltage Rating: The cable may have a specific voltage rating,indicating the maximum voltage it can handle safely during

    operation.

Features

  • Low Signal Attenuation: The cable is designed to minimizesignal attenuation, ensuring reliable and high-quality signal

    transmission over long distances.

  • Easy Termination: The cable is designed for easy termination,allowing for efficient and hassle-free installation. It may feature

    convenient termination options such as connectors or insulation

    displacement connectors (IDCs).

  • Flexible and Durable: The cable is flexible and durable,allowing for easy handling, routing, and installation in various

    environments. It can withstand bending and twisting without

    compromising its performance.

  • Wide Temperature Range: The cable is designed to operatewithin a wide temperature range, ensuring its suitability for both

    indoor and outdoor applications.

  • UV Resistant: The cable’s outer jacket is UV resistant,protecting it from damage and degradation caused by prolonged

    exposure to sunlight.

  • Moisture Resistance: The cable is resistant to moisture,preventing water ingress and maintaining its performance even in

    humid or damp conditions.

  • Plenum Rated: The cable is plenum-rated, meeting stringentfire safety requirements for installation in plenum spaces. It is

    designed to minimize the spread of fire and reduce smoke

    emissions.

  • RoHS Compliance: The cable is compliant with the Restrictionof Hazardous Substances (RoHS) directive, ensuring it is free from

    hazardous materials, such as lead or mercury.

  • EMI/RFI Protection: The cable provides effective protectionagainst electromagnetic interference (EMI) and radio frequency

    interference (RFI), maintaining signal integrity in the presence of

    external electromagnetic sources.

  • Versatile Applications: The cable is suitable for a wide range ofapplications, including audio systems, communication networks,

    security systems, and more.

  • Longevity: The cable is designed for long-term performanceand durability, ensuring reliable operation over an extended

    period.

  • Easy Identification: The cable’s white color allows for easyidentification and differentiation from other cables during

    installation or maintenance.

  • Flammability Rating: The cable may have a specificflammability rating, such as UL 1666 (Riser) or UL 1685 (Vertical

    Tray), indicating its resistance to flame propagation.