AIPHONE AX-084C Central Exchange Unit For 8 Doors / Subs, 4 Masters
Features
-
- Wiring hub for AX system using Cat-5e
- Two 24V DC power supply input terminals
- Rack mountable
- Controls all functionality of AX system
- Two BNC composite video outputs and video switching triggers
- CO line transfer (requires Viking K-1900-5 programmable auto-dialer)
- Programmable functionality via supplied software
Specification
- Consumption: Video: 0.62A max. Audio: 0.65A max
- CO Line Port: RJ11 for Viking K-1900-5 programmable auto-dialer
- Door Release: Programmable dry contact, 24V AC/ DC, 500mA – use EL-12S (use RY-24L for larger contact rating)
- Mounting: 19″ EIA rack (2U) or wall mount
- Wire Type: Between Door / Sub Station, Master Station, and Central Exchange Unit: Cat-5e
- Power Supply to Central Exchange Unit and Add-On Central Exchange Unit: 2-cond., overall shield – use Aiphone 821802
- Wire Distance: Door / Sub Station to Central Exchange Unit and Add-On Central Exchange Unit: 980′
- Central Exchange Unit to Master: 980′
- Central Exchange Unit to Add-On Central Exchange Unit: 16′
- Power Supply to Central Exchange Unit and Add-On Central Exchange Unit: 16′(22AWG) 33′(18AWG)