Nexlar E-Commerce

Larson Electronics EPFDS-16A-3P-3X16A.600V-TD 16A Explosion Proof Fused Disconnect – Class I,II,III – Time Delay Fuse – (3) 16A 600V (4) Cast Hubs

SKU : EPFDS-16A-3P-3X16A.600V-TD Category

16A Explosion Proof Fused Disconnect – Class I,II,III – Time Delay Fuse – (3) 16A 600V (4) Cast Hubs

Larson Electronics EPFDS-16A-3P-3X16A.600V-TD 16A Explosion Proof Fused Disconnect – Class I,II,III – Time Delay Fuse – (3) 16A 600V (4) Cast Hubs

 

Description:

The Larson Electronics EPFDS-16A-3P-3X16A.600V-TD Explosion Proof Fused Disconnect is designed for use in Class I, II and III environments. Equipped with time-delay fuses, this 3-pole unit contains three 16-amp 600V fuses and four NPT hubs. The explosion proof disconnect offers delayed response to transient surges, making it ideal for addressing pulse currents and temporary overloads associated with motors, HVAC systems and HID lights in flammable work sites.

*PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO EXPLOSION PROOF ENCLOSURES*

The EPFDS-16A-3P-3X16A.600V-TD ensures active protection of electrical systems in combustible facilities. This fused unit contains three 16-amp 3-pole 600V time-delay fuses. The fuses feature 10-second time delay at 500% overload. These explosion proof disconnects are not sensitive to electrical pulses, allowing connected systems to utilize more power without activating the fuse. Time-delay fuses (also known as a short-blow fuse or a slow-blow fuse) can withstand electrical surges for a specific period of time, typically 10-15 seconds. This feature is useful for equipment that relies on high voltage current during startup, such as motors.

The explosion proof disconnect switch/breaker is made of cast aluminum and features a rectangular bolted cover design for uniform and attractive installations. The cover bolts are made from stainless steel. The external on/off lever can be locked into the “off” position with room for up to three padlocks for superior security. The internal circuit breaker handle mechanism is a sliding plate type mounted to the cover. The circuit breaker is trip free of the external handle mechanism.

Hubs: For completing electrical connections, four NPT hubs are provided on the enclosure. Two cast 2″ conduit hubs are located at the north side and south side of the unit (one 2″ NPT hub per side); and two cast 0.5″ NPT hubs can be found at the north side and south side of the disconnect (one 0.5″ NPT hub per side).

Mounting: Operators can mount the explosion proof disconnect on flat surfaces.

Applications: Motors, VFDs, phase converters, HVAC systems, dryers, fluorescent lights, HID lights, metal halide, high pressure sodium, mercury vapor, petroleum refineries, chemical and petrochemical plants, storage areas, and other processing facilities where hazardous substances are handled or stored.

Features:

  • Unit Type: Explosion Proof Disconnect Switch (Fused)
  • Dimensions: –
  • Weight: 10.5 lbs
  • Voltage: 600V AC or 125V DC (Maximum)
  • Configuration: 3-Pole
  • Amps: 16A
  • Fuse Type: Time Delay Fuse
  • Time Delay: 10 Seconds (Minimum) @ 500% Overload
  • Fuses: (3) 16A 3P [600V]
  • Materials: Cast Aluminum
  • Hardware Materials: Stainless Steel
  • Mounting: Surface Mount
  • Hub Qty: 4
  • Hub Sizes/Location: (2) 2″ NPT (North + South Side), (2) 0.5″ NPT (North + South Side)
  • Conduit: Operator Provided
  • *All grounding shall comply with state and local codes and meet the minimum requirements of the National Electronic Code section 250*
Weight 10.5 lbs
Brand

Reviews

There are no reviews yet.

Be the first to review “Larson Electronics EPFDS-16A-3P-3X16A.600V-TD 16A Explosion Proof Fused Disconnect – Class I,II,III – Time Delay Fuse – (3) 16A 600V (4) Cast Hubs”

Your email address will not be published. Required fields are marked *

EPFDS-16A-3P-3X16A.600V-TD Spec Sheet

Download