DoorKing 2600-588 Heater Kit for 1812 units
The kit includes a heating element that generates controlled heat
to keep the internal components of the Telephone Entry System at
an optimal operating temperature. This heating element prevents
the formation of ice, frost, or condensation that can affect the
system’s operation.Temperature Control: The heater kit features
temperature control capabilities to maintain a consistent and
desired temperature range. This ensures that the Telephone Entry
System remains within optimal operating conditions without
overheating.Easy Installation: The DoorKing 2600-588 Heater Kit is
designed for straightforward installation. It includes all necessary
components and instructions, simplifying the process for
integration with the DoorKing 1812 Telephone Entry System.
Compatibility: The heater kit is specifically designed for
compatibility with DoorKing 1812 Telephone Entry Systems. It
seamlessly integrates with the system, ensuring a proper fit and
reliable performance.Energy Efficiency: The heater kit is energy
efficient, consuming only the required amount of power to
maintain the optimal operating temperature. This feature
minimizes energy consumption and reduces operating costs.
Weather Resistance: The heater kit is designed to withstand
various weather conditions. It may feature weather-resistant
materials, protective coatings, or an IP (Ingress Protection) rating
to ensure durability and protection against dust and water ingress.
Safe Operation: The heater kit is designed for safe operation. It
incorporates safety features such as thermal protection and
insulation to prevent overheating and electrical hazards.
Warranty: The manufacturer may provide a warranty period for
the heater kit, offering protection against defects in materials or
workmanship. The warranty duration can vary, typically ranging
from one to three years.
Specifications
- Heating Element Power: The heater kit typically has aspecified power rating, indicating the amount of heat it can
generate. Common power ratings for heater kits range from 50
watts to 150 watts, depending on the specific model.
- Voltage Compatibility: The heater kit is designed to operatewithin a specific voltage range. Common voltage options include
120VAC or 240VAC, ensuring compatibility with the power supply
of the Telephone Entry System.
- Operating Temperature Range: The heater kit is designed tofunction within a specific temperature range. It may have an
operational temperature range of, for example, -40?C to +50?C (-
40?F to +122?F), allowing it to provide consistent heat in extreme
cold environments.
- Mounting Options: The kit may offer different mounting optionsto accommodate various installation requirements. It may include
mounting brackets, adhesive backing, or other mechanisms to
securely attach the heater to the Telephone Entry System
enclosure.
- Size and Dimensions: The heater kit has specific dimensionsthat determine its physical size and shape. These dimensions
ensure proper fit and integration with the DoorKing 1812
Telephone Entry System enclosure or housing.
- Energy Consumption: The heater kit may provide informationabout its energy consumption, typically measured in watts or
kilowatt-hours. This specification helps estimate the operating
costs associated with using the heater kit.
- Compliance with Standards: The heater kit may comply withrelevant industry standards and certifications, ensuring its safety,
performance, and reliability. These standards may include UL
(Underwriters Laboratories) listing or CE (Conformit? Europ?ene)
certification.
- Weatherproof Design: The heater kit is designed to beweatherproof, with features such as sealed components and
weather-resistant materials. This design ensures durability and
reliable performance in harsh weather conditions.
- Warranty: The manufacturer may provide a warranty period forthe heater kit, offering protection against defects in materials or
workmanship. The warranty duration can vary, typically ranging
from one to three years.
Features
- Thermostat Control: The heater kit may include a built-inthermostat that allows for precise temperature control. This
feature ensures that the heater maintains the desired temperature
range, optimizing energy efficiency and preventing
overheating.
- Automatic Activation: Some heater kits are designed toautomatically activate when the ambient temperature falls below
a certain threshold. This feature eliminates the need for manual
intervention and ensures that the system is protected even when
unattended.
- LED Indicator: The heater kit may have an LED indicator thatprovides a visual indication of the heater’s status. This feature
allows for quick and easy monitoring of the heater’s operation and
ensures that it is functioning properly.
- Remote Monitoring and Control: Advanced heater kits mayoffer remote monitoring and control capabilities. This feature
allows you to monitor the heater’s status and adjust its settings
remotely using a compatible device or system.
- Timer Functionality: The heater kit may include a timerfunction that allows you to schedule specific heating periods. This
feature provides flexibility in controlling when the heater
operates, allowing you to optimize energy usage and tailor it to
your specific needs.
- Self-Regulating Heating Element: Some heater kits featureself-regulating heating elements. These elements automatically
adjust their heat output based on the ambient temperature,
providing efficient and consistent heating while preventing
overheating.
- Low Power Consumption Standby Mode: To further enhanceenergy efficiency, the heater kit may have a low power
consumption standby mode. This mode reduces power usage when
the heater is not actively heating, minimizing energy waste.
- Multiple Heating Zones: Advanced heater kits may offermultiple heating zones that can be individually controlled. This
feature allows you to customize the heating settings for different
areas within the DoorKing 1812 Telephone Entry System enclosure,
optimizing heat distribution.
- Maintenance Alerts: The heater kit may have built-in sensors ormonitoring capabilities that can detect potential issues or
maintenance requirements. It can provide alerts or notifications to
indicate when servicing or inspections are necessary.
Reviews