Nexlar E-Commerce

Larson Electronics EXP-MS-EMG-N4X-AT-HV-V2-10W-120V 10W Explosion Proof Motion and Light Sensor w/ 3HR Emergency Backup – 120V – 59′ Max Mounting Height – 52.4′ x 49.2′ Detection Zone

SKU : EXP-MS-EMG-N4X-AT-HV-V2-10W-120V Category

10W Explosion Proof Motion and Light Sensor w/ 3HR Emergency Backup – 120V – 59′ Max Mounting Height – 52.4′ x 49.2′ Detection Zone

Larson Electronics EXP-MS-EMG-N4X-AT-HV-V2-10W-120V 10W Explosion Proof Motion and Light Sensor w/ 3HR Emergency Backup – 120V – 59′ Max Mounting Height – 52.4′ x 49.2′ Detection Zone

 

Description:

The Larson Electronics EXP-MS-EMG-N4X-AT-HV-V2-10W-120V Explosion Proof Motion and Day/Night Sensor with Emergency Battery Backup is approved for Class I, Division 1 and Class II, Division 1 flammable work sites. This 10-watt device, which is capable of detecting both motion and ambient light, is an energy efficient and automated solution to lighting controls in industrial facilities. The explosion proof unit can be mounted on ceilings or walls and features compatibility with 120V AC.

The EXP-MS-EMG-N4X-AT-HV-V2-10W-120V is ideal for operators seeking a high quality explosion proof motion and day/night sensor rated for use in Class I, Division 1 and Class II, Division 1 flammable work sites. This explosion proof unit operates on 120V AC and features the following modes: Disable and Sensor. For motion detection, the sensor can detect movement at a rate of 0.5~3m/s. When connected to a fixture, the 10-watt sensor ensures the lamp stays off when ambient light in the area is sufficient. At night, as the sensor detects insufficient ambient light in the environment, the device engages the fixture to turn on when motion is detected. During operation, the sensor adheres to the configured hold time. When motion is detected and the hold time is complete, the fixture turns off. Please note: when used as both day/night and motion sensor, this unit will only enable motion once ambient light has fallen below the required lux setting. This WILL NOT activate when lux falls below threshold. The day/night setting is designed to limit the motion sensor so the motion sensor is only activate at night.

Emergency Battery Backup: The EXP-MS-EMG-N4X-AT-HV-V2-10W-120V features a battery backup feature that adds emergency functionality to the sensor. This component will run the pass-thru sensor for 3 hours or 180 minutes in the event of power failure or outage. The system recharges the battery once electrical power is restored. Standard configuration includes a single emergency battery backup that is automatically recharged and kept in a ready state. This inline emergency battery can be remote mounted during installation at the site.

Motion Detected Through a Wall
This unit leverages cutting-edge microwave sensors to detect motion. When in use, the device sends out discreet waves that are reflected back from nearby walls and objects (not heat or light). Microwave sensors are not affected by line of sight, resulting in wider and more accurate coverage of the target area. By comparison, traditional infrared sensors can only detect heat and light (factors used to identify movement) within the unit?s field of view. Microwave sensors also provide stable performance in unpredictable climates and can penetrate glass, plastic and other non-metallic objects.

Reach Setting: For best results, it is recommended to adjust the sensitivity of the unit by configuring the reach setting. Reach is the term used to describe the radius of the circular detection zone produced on the ground. This device provides a maximum detection zone of 52.4` x 49.2`. After mounting the sensor at the desired height, operators can adjust distance sensitivity.
Ceiling Mount
Wall Mount
Mounting: The explosion proof motion and day/night detector can be mounted on ceilings or walls. When mounted on the ceiling, the sensor offers detection at distances up to 59 feet (from the ceiling) and 360 degrees of detection (see chart). When mounted on a wall, the maximum distance of detection is 98.4 feet, with 150 degrees of detection (see chart).

Suggested Applications: Manufacturing, Industrial, Warehouse, Lighting, Lighting, Wet areas or Locations Where Combustible Dust is Present.

Features:

    • Listing: NRTL Listed for United States, Canada and IECEx/ATEX Rated
    • Dimensions: 7″-W x 5″-H x 9″-D
    • Detection: Motion, Motion+Day/Night
    • Detection Coverage: 52.4` x 49.2` – Maximum
    • Tilt Angles: 150? – Wall; 360? – Ceiling
    • System Voltage: 120V AC
    • Rated Load: 10W @ 120V
    • Transmitting Power: <0.5mW
    • Wiring: Flying Leads
    • Power Consumption: =0.5W (Standby)
    • Motion Detection: 0.5~3m/s
    • Output Hold Time: 5s / 30s / 90s / 3min / 20min / 30min
    • Daylight Sensor: 5Lux/ 15Lux /30Lux /50Lux /100Lux / Disabl

e

  • Emergency Backup Duration: 3 Hours (180 Minutes)
  • Emergency Battery Location: Inline, Remote Mount
  • Daylight Sensor: 5Lux/ 15Lux /30Lux /50Lux /100Lux / Disable
  • Ambient Temperature Range: -20C ~ 60C
  • Radiated Frequency: 5.8GHz ? 75MHz, ISM Wave Band
  • Mounting Distance: 59` (Ceiling), 98.4` (Wall)
  • Color: Gray